Back to section: troubleshooting
How to check if the solenoid valve is working correctly?
Despite pressing the button crimper does not react?
Perform the following steps to check.
1. If the crimper has been moved to a different location (to a different power socket), check the direction of the motor rotation (if necessary, change phases L1 to L3 in the socket)
Checking the hydraulic solenoid valve
2. If the motor rotation is correct, check if the solenoid valve located under the head is working properly
- check if the solenoid valve coils are working (press the crimping button and check if the coil lights up red, check opening and check the second coil)

- press the point marked in the photo to mechanically check if solenoid valve will work (this is a way to control crimping and opening without an electrical signal from the coil). All you need is an Allen key and to press the marked point for the solenoid valve to start working (crimping or opening) depending on whether we pressed the left or right valve.

These are things you can do yourself without fear of damaging the machine
In the event that the main jaws are not working (opening or closing). By pressing the opening or closing button, we check if the indicator lights on the solenoid valve (under the head, two coils on the sides) light up; both should light up when pressed. If the LED on the coil does not light up, we unscrew the front panel of the machine (Allen screws) and plug in the cable block, which most likely slipped out of the control board. (The blocks are labeled and matched by size to avoid mistakes). In other cases, the solenoid valve spool most likely got stuck. In such a case, we use a Phillips screwdriver to unscrew both blocks coming to the solenoid valve (under the head). Next, using an Allen key, we unscrew the four Allen screws with which the solenoid valve is tightened to the manifold block.
Checking the solenoid valve
I suggest placing a small cloth under the solenoid valve as some oil will seep out after unscrewing. After removing the solenoid valve, we visually check if there is any mechanical contamination in the four channels causing it to stick. There are four small O-rings in the channels, so be careful not to lose them. Next, we unscrew the two coils on the sides and check if the plungers on both sides are working. Sometimes just tapping it is enough to unblock the plunger. In the case of a stuck solenoid valve, the jaws do not close, or the jaws close all the way until an overload is heard; in such cases, the machine must be disconnected immediately. It may even happen that under pressure the direction of the motor rotation changes, but these are extreme situations.
See also: