Damage to the front panel in a swaging machine
Cracking of the swaging machine's front plate is a consequence of over-crimping ( pumping with the pump after reaching the required diameter ). In the case of electric swaging machines, this type of damage can occur through incorrect die selection or crimping elements such as rods. To avoid this type of damage, we must remember the basic rules regarding hydraulic hose crimping :
- Each hose is crimped to a specific diameter ( according to the crimping table )
- We select the most suitable dies
- After the indicator light comes on, do not crimp any further. The light informs us that the diameter we set has already been reached. If the dies have closed completely, we cannot continue pumping because the swaging machine head will continue to move toward the front plate > it will cause damage to the seals or a crack in the front plate because the piston will push the head forward.

Example of damage ( front plate crack ) in a P16HP manual hose swaging machine ( extreme example )

A head crack is a typical mechanical damage ( not covered by warranty ) It is not possible to achieve this effect during normal operation of the swaging machine - if we follow the crimping instructions and correctly select the crimping dies, there is no possibility of this happening to us.