back to : SAMWAY S51 hose crimping machine
User manual for the SAMWAY S51 hose crimping press
S51 Crimping machine - note: the videos show an old version of the crimping machine !
After connecting the machine to the power source with a 16A-6h plug (5-pin round plug), check the direction of motor rotation.

Checking the hose crimping diameter
Tip: Crimping a DN10 2SN hose with the S51 crimping machine. During the first crimp, you need to know what kind of hose it is. Hoses have markings for their parameters. If you cannot read the values on the hose, first measure the inner diameter of the hose using a caliper. Then visually determine how many steel braids (wire braids) it has inside. Next, select the appropriate ferrule and hose fitting. Then check the approximate crimping chart for the dimension to which the hose should be crimped. Example: DN 10 mm ( 3/8 inch) 2SN - double-braid hose. Knowing the hose parameters, we look in the approximate crimping table for the value to which we should crimp the hose. In the case of a DN 10 2SN hose, we read the value 20,6 mm in the table.
Selecting the appropriate crimping dies
Next, we select the dies closest to the 20,6 mm parameter, following the rule that the die size must be smaller than the 20,6 mm value. In this case, these are 19 mm dies. Next, using a simple mathematical operation, i.e. 20,6 mm - 19 mm = 1,6 mm. The difference after subtracting these values gives us the parameter to be set on the micrometer, which in this case is 1,6 mm. After fitting the 19 mm dies, we proceed to set the value of 1,6 mm on the micrometer. Use the micrometer knob to set the desired value. The micrometer should be zeroed before setting. Zeroing consists of setting the knob in a position where the digit 0 meets the digit 0. Turning the micrometer knob to the right, we set 1,6 mm and proceed to crimp the hose. Remember to crimp the ferrule on the hose twice. During the first crimp, a ridge forms on the ferrule, which must be leveled by a subsequent crimp. This operation is performed by rotating the ferrule on the hose so that the dies press down on the ridge formed in that place.
Setting the micrometer:
Two full turns of the micrometer knob give a value of 1. Mikrometr znajduje się w górnej części głowicy.
Installing dies in the S51 crimping machine
Removing dies from the S51 crimping machine
Tip:
In the S51 crimping machine, we remove and install the dies using a tool. Each type of die has its numbering stamped on it. We seat the die using the tool, which we place on the pin in the master dies. After pulling back - releasing the pin, the die is seated in the hole without any resistance. After removing the tool, the pin in the die we are using clicks into the lock of the master dies.