Skip to main content


Fluid power hydraulics - parts, accesories

Experienced Polish manufacturer & direct distributor of hydraulic components   
Retail & Wholesale – One-Stop Industrial Supplier | 100% European-owned    
   

six-time winner
Business Gazelles 2024

NATO supplier
Code 99Q4H
HYDRON NCAGE code

proven reliability
HYDRON DUNS number

authorized
service
Authorized ENERPAC Service Center in Poland

official
distributorUSA
Authorized ENERPAC distributor in Poland

official distributorEU SEMPERIT distributor

quality assurance
ISO 9001, TUV
HYDRON ISO certificates

📦 15,000+ items in our stock & ready to ship
⚡ Fast shipping 🛡️ Quality guarantee 🛠️ Technical support
Products in the cart: 0. See details
Your cart is empty

Micrometer calibration in a crimping machine

back to : FAQ - crimping machine troubleshooting or crimping machine micrometers

 Micrometer calibration in a crimping machine

Micrometer calibration in the P32Q electric crimping machine

In the case of calibration in a crimping machine with a P32Q analog micrometer we can calibrate the micrometer ourselves. After inserting dies e.g. with number 19 and setting the value 1.60 on the micrometer, we first crimp a DN 10 2SN hose. Then we measure the crimped ferrule using a caliper. If the value indicates e.g. 21.4 it means that the crimping machine is under-crimping. We must then calibrate the micrometer. The crimp should be within 20.6 or 20.7. Therefore, the micrometer dial handle should be unscrewed using a very small Allen key. We take care not to lose this small locking screw holding the dial. Then very gently remove the dial and set it aside. A small pin will be revealed with which we have the possibility to calibrate the micrometer by turning it left or right. So having the number 19 dies inserted, set the micrometer dial to 1.60. Once the dies are crimped until the indicator light on the switch turns on, we proceed to unscrew the micrometer handle dial. We unscrew the small locking screw holding the handle. Then by gently turning the small pin to the left, we cause the indicator light to go out, thus the dies will crimp tighter. We assemble the micrometer dial handle by gently seating it back in its place and tightening the locking screw. After removing the micrometer dial, it will show a delicate metal plate with two protruding pins inside (these are very small delicate elements). Therefore, we pay attention so that the protruding plates from the micrometer are evenly seated in the same holes in the handle. We crimp again, making another measurement of the crimped ferrule. If we have not obtained the desired crimp parameter, we repeat this action until we obtain a correct crimp.

P32D MICROMETER CALIBRATION ( DIGITAL CRIMPING MACHINE )

In the case of a crimping machine with digital control, we also have the option to calibrate the micrometer (model P32D). Calibration is also performed by inserting dies e.g. number 19 and setting parameter 1.60 on the digital display using the SHIFT button. As a reminder, all digits after setting must be steady and must not flash. Of course, DN10 2SN hose – crimp to 20.6 mm. In this case, we also crimp the hose and measure the crimped ferrule using a caliper. If we have a value other than 20.6 or 20.7, we proceed to calibrate the micrometer. Behind the crimping head at the bottom of the head, we have an Allen screw screwed into the head – it is secured with a nut for a 10 mm wrench. In the first place, we loosen the nut on the union where we have two nuts – loosen it gently. Then we loosen the nut on the Allen screw screwed into the head and completely unscrew the long black Allen screw. Turning left or right after unscrewing  completely the black Allen screw allows us to calibrate the micrometer. This is why we first loosened the locking screw for the long silver union, to have room to maneuver for tightening or unscrewing the screw regulating the closing or opening of the master dies. We calibrate the micrometer by turning the entire union with the black Allen screw to the right or left. To start, e.g. two or three turns tightening or loosening the whole set are enough. Depending on whether it is under-crimping or over-crimping. We lock all screws back and crimp again, checking the crimp diameter. We repeat this action until the desired crimp parameter is achieved. 

 

 micrometer calibration in a digital crimping machine

MICROMETER CALIBRATION INSTRUCTIONAL VIDEO 

Read also : how to use the micrometer without damaging it