Micrometer calibration in the P32Q electric crimping machine
In the case of calibration in a crimping machine with the P32Q analog micrometer we can calibrate the micrometer ourselves. After seating the dies, e.g. with number 19, and setting the value 1.60 on the micrometer, we first crimp a DN 10 2SN hose. Then we measure the crimped ferrule using a caliper. If the value indicates, for example, 21.4, it means the crimping machine is under-crimping. In that case, we must calibrate the micrometer. The crimp should be within 20.6 or 20.7. Therefore, you should unscrew the micrometer dial handle using a very small Allen key. Be careful not to lose that small locking screw for the dial. Then very gently remove the dial and set it aside. A small pin will be revealed, which allows us to calibrate the micrometer by turning it left or right. So, with number 19 dies inserted and the micrometer dial set to 1.60. Once the dies are crimped until the indicator light on the switch turns on, we proceed to unscrew the micrometer handle dial. We unscrew the small locking screw for the handle. Then, by gently turning the small pin to the left, the indicator light goes out, which means the dies will crimp more tightly. We assemble the micrometer dial handle by gently putting it back in its place and tightening the locking screw. After removing the micrometer dial, a delicate metal plate with two protruding pins will be visible inside ( these are very small, delicate parts). Therefore, we pay attention to ensure that the protruding plates from the micrometer are evenly seated in the same holes of the handle. We crimp again and take another measurement of the crimped ferrule. If the desired crimping parameter has not been achieved, we repeat this process until correct crimping is achieved.
P32D MICROMETER CALIBRATION ( DIGITAL CRIMPING MACHINE )
In the case of a crimping machine with digital control, we also have the option to calibrate the micrometer (model P32D). Calibration also takes place by seating the dies, e.g. number 19, and setting parameter 1.60 on the digital display using the SHIFT button. As a reminder, all digits must be solid after setting; they must not blink. Of course, DN10 2SN hose – crimping at 20.6 mm. In this case, we also crimp the hose and measure the crimped ferrule using a caliper. If we have a value other than 20.6 or 20.7, we proceed to calibrate the micrometer. At the back of the crimping machine head, at the bottom of the head, we have an Allen screw screwed into the head – it is locked with a size 10 nut. First, we loosen the nut on the fitting where we have two nuts – we loosen it gently. Then we loosen the nut on the Allen screw screwed into the head and completely unscrew the long black Allen screw. Turns to the left or right after unscrewing completely the black Allen screw allow us to calibrate the micrometer. The reason we first loosened the locking screw for the long silver fitting was to have room to maneuver for tightening or loosening the screw that regulates the closing or opening of the master dies. We calibrate the micrometer by turning the entire fitting with the black Allen screw clockwise or counter-clockwise. To start, two or three turns should be enough, tightening or loosening the whole assembly. Depending on whether it's over-crimping or under-crimping. We lock all screws back in place and crimp again, checking the crimp diameter. We repeat this process until the desired crimp parameter is achieved.

MICROMETER CALIBRATION INSTRUCTIONAL VIDEO
Also read : how to use a micrometer without breaking it