Pneumatic crimping machine user manual SAMWAY P20AP
Step-by-step hose crimping on the P20AP crimper - pneumatic crimper operation.

Installing and removing dies on the P20AP crimper
Setting the micrometer of the P20AP crimper
Tip: When using the micrometer knob, primarily try not to turn the micrometer below the zero value. Blow out the area around the knob with compressed air to remove accumulated sediment. Keeping the micrometer clean prevents its failure.
Hose crimping on the P20AP crimper
Tip: During the first crimp, you must know what hose it is. The hoses have markings for their parameters. If you cannot read the values on the hose, first measure the inner diameter of the hose using a caliper. Then visually determine how many steel braids it has inside, the so-called layers. Next, select the appropriate ferrule and hose fitting. Then check the indicative crimping table for the dimension the hose should be crimped to.
Example: DN 10 mm ( 3/8 inch) 2SN hose - double-braid hose. Knowing the hose parameters, we look in the indicative crimping table for the value to which we are to crimp the hose. For a DN 10 2SN hose, we read the value 20,6 mm in the table. Then we select the dies closest to the 20,6 mm parameter, applying the rule that the die size must be smaller than the 20,6 mm value. In this case, these are 19 mm dies. Next, using a simple mathematical operation, i.e., 20,6 mm - 19 mm = 1,6 mm. The difference after subtracting these values gives us the parameter we need to set on the micrometer, which in this case is 1,6 mm. After installing die number 19 and setting the value of 1,6 mm on the micrometer, we proceed to crimp the hose. Remember to crimp the ferrule on the hose twice. During the first crimp, a ridge is formed on the ferrule, which we must eliminate through a subsequent crimp. This is done by turning the ferrule on the hose so that the dies press down on the ridge formed at that spot
Bleeding the P20AP crimper pump
Tip: The pneumatic crimper should be bled before crimping the hose. Locate the screw on the oil tank that is screwed in with a Phillips screwdriver. There is an inscription there. " CAUTION RESERVOIR MUST BE VENTED PRIOR TO USE". This inscription informs: Attention Reservoir must be vented before use. Very important: the pump operates in the range from 2,76 - 8,27 bar. The manufacturer recommends installing an ENERPAC RFL-102 air pressure regulator and lubricator. The main cause of oil tank leakage is a faulty compressor that provides too much pressure or cannot maintain constant pressure. In such a case, oil may leak from under the tank gasket or the head release vent plug.


Hose crimping - general information about the P20AP crimper