User manual for P20HP crimping machine

back to : SAMWAY P20HP manual crimper

Manual for the SAMWAY P20HP manual hose crimping machine

this is an older version of the crimping machine ( without the quick die change system ) 

User manual for the P20HP manual crimper

Checking the crimping diameter on the table 

On the presented crimper model, the following was crimped: DN10 3/8 inch 2SN hose (two-wire braid hose). After determining the internal diameter of the hose and assessing the number of steel braids inside, we proceeded to find in the approximate crimping table the value to which the hose should be crimped. According to the table, the hose should be crimped to a value of 20.6 mm.

Selection of appropriate crimping dies

Next, the closest dies to the value of 20.6 mm were selected, following the principle that they must be dies smaller than the table value. In this case, these are size 19 dies. Then, numbered dies from 1 to 8 of size 19 were placed inside the main dies. Subsequently, a value of 1.60 was set on the micrometer by turning the micrometer knob to the right. ( 19+ 1.60 =20.6 mm). Next, the oil filler plug was loosened and the butterfly nut on the pump was tightened.

Hose crimping 

After seating the crimping ferrule along with the fitting on the hose we proceeded to crimping. Crimp until the indicator light on the micrometer turns on. After the first crimping, we proceed to crimp again to eliminate the notch on the ferrule that was created after the first crimp. After double crimping, we are certain that the ferrule on the hose has been properly compressed. Next, we zero the micrometer using the knob (turning it to the left) and loosen the pump's butterfly nut, which will cause the crimped dies to open. We advise doing this gently so that the accumulated pressure does not cause oil to leak from under the filler plug. In the final stage, using the pin supplied with the crimper, we extract each of the dies from inside the head. Check also : hydraulic hose crimping instructions ( expanded )