back to : SAMWAY P20AP pneumatic crimping machine
Pneumatic crimping machine user manual SAMWAY P20AP
Crimping a hose on the P20AP crimper step by step - operating a pneumatic crimping machine.

Installing and removing dies for the P20AP crimper
Micrometer setting for the P20AP crimper
Tip: When using the micrometer knob, try first and foremost not to turn the micrometer below zero. Blow out the area around the knob with compressed air to remove accumulated debris. Keeping the micrometer clean prevents its failure.
Crimping a hose with the P20AP crimper
Tip: During the first crimp, you must know what kind of hose it is. Hoses have markings of their parameters. If you cannot read the values on the hose, first measure the inner diameter of the hose using a caliper. Then visually determine how many steel wire layers (so-called braids) it has inside. Next, select the appropriate ferrule and hose fitting. Then, check the approximate crimping table for the dimension the hose is to be crimped to.
Example: DN 10 mm ( 3/8 inch) 2SN hose - two-wire braid hose. Knowing the hose parameters, we look for the value to which the hose should be crimped in the approximate crimping table. In the case of a DN 10 2SN hose, we read the value 20,6 mm from the table. Then, we select the dies closest to the 20,6 mm parameter, following the rule that the die size must be smaller than the 20,6 mm value. In this case, these are 19 mm size dies. Next, using a simple mathematical calculation, i.e., 20,6 mm - 19 mm = 1,6 mm. The difference after subtracting these values gives us the parameter to be set on the micrometer, which in this case is 1,6 mm. After installing die set number 19 and setting the micrometer value to 1,6 mm, we proceed to crimp the hose. Remember to crimp the ferrule on the hose twice. During the first crimp, a ridge forms on the ferrule, which we must eliminate by a subsequent crimp. This is done by rotating the ferrule on the hose so that the dies press down on the formed ridge
Bleeding the P20AP crimper pump
Tip: The pneumatic crimper should be bled before crimping a hose. On the oil reservoir, find the screw driven with a Phillips screwdriver. There is an inscription there. " CAUTION RESERVOIR MUST BE VENTED PRIOR TO USE". This inscription informs: Attention, the reservoir must be vented before use. Very importantly, the pump operates in the range of 2,76 - 8,27 bars. The manufacturer recommends installing an ENERPAC RFL-102 air pressure regulator and lubricator. The main cause of oil reservoir leakage is a faulty compressor that provides too much pressure or cannot maintain a constant pressure. In such a case, oil leakage may occur from under the reservoir gasket or the head release valve plug.


Hose crimping - general information about the P20AP crimper
Check also : hydraulic hose crimping manual ( extended )