User manual for SAMWAY P20Q crimping machine

Hose crimping
First crimping step by step
After connecting the crimper to a power source (5 pin 16A plug - 3 phase power supply) start the machine using the red switch. Important: the motor rotor rotation must be clockwise for the oil suction pump to work correctly. In case of counter-clockwise rotation the phases inside the plug must be swapped. Underneath the machine is a table in which the dies are set. In the P20Q model we have the following crimping die sizes : 14,16,19,22,26,30,34,39,45. The provided die dimensions specify their internal diameter size after crimping. In the presented instructional video a DN6 1SN hose was used (inner diameter of the hose 6 mm - single braid hose.
Selecting the dies
To select the correct dies check the GENERAL CRIMPING TABLE for the diameter to which the hose is to be crimped. In the vertical column we have the internal diameters of the hose starting from 5 mm 3/16 inch up to 50 mm 2 inches. The horizontal part of the table presents the types of hoses starting from thin walled hoses and ending with 4-braid hoses. When selecting the appropriate dies for the hose to be crimped follow the rule: WE SEARCH FOR THE DIE SIZE CLOSEST TO THE CRIMPING DIAMETER ACCORDING TO THE GENERAL CRIMPING TABLE. The used dies must always be smaller than the parameter specified in the general crimping table. For a DN6 1SN hose the crimp according to the table is 15, 7mm. Therefore we use die number 14 because the next size is 16 and is too large. Next we set the desired value using the micrometer. Remember when fitting any dies the micrometer must be zeroed. By turning the micrometer knob to the right set the value to 1,70 mm. ( die size 14 + 1,7 = 15,7 mm). Next we place the hose with the ferrule containing the fitting and proceed to the first crimp. When placing the hose for crimping remember that the ferrule should be slightly hidden in the dies you are crimping with. By pressing the die closing button we crimp the ferrule. After the first crimp a ridge will appear, which should be eliminated by crimping again. At the very end the micrometer should be zeroed using the knob. Then close the dies to the very end. Insert the quick change tool. Open the dies using the button and remove them from the inside.
SAMWAY P20Q crimping machine