back to : fittings for connecting precision tubes
Mounting cutting rings on a tube
Cutting ring assembly instructions
1. Cut the tube at a right angle. A deviation of 0.5º from the right angle is permissible.
2. Remove internal and external burrs (you can use a deburring tool )
3. For thin-walled tubes as well as those made of aluminum or copper, reinforcement sleeves should be used.
4. Minimum lengths of the straight tube section must be maintained according to the table below.

|
Series |
LL |
L |
S |
|||||||||||||||||||||
|
tube ext. diameter |
4 |
5 |
6 |
8 |
6 |
8 |
10 |
12 |
15 |
18 |
22 |
28 |
35 |
42 |
6 |
8 |
10 |
12 |
14 |
16 |
20 |
25 |
30 |
38 |
|
H min. |
24 |
25 |
25 |
26 |
31 |
31 |
33 |
33 |
36 |
38 |
42 |
42 |
48 |
48 |
35 |
35 |
37 |
37 |
43 |
43 |
50 |
54 |
58 |
65 |
|
L min. |
30 |
32 |
32 |
33 |
39 |
39 |
42 |
42 |
45 |
48 |
53 |
53 |
60 |
60 |
44 |
44 |
47 |
47 |
54 |
54 |
63 |
68 |
73 |
82 |
LUBRICATION
All our fittings are coated with a colorless lubricant. Additional lubrication of fittings with diameters smaller than 20 mm is not necessary. In case of disassembly and reassembly, the fittings should be oiled.
ASSEMBLY USING WRENCHES (for single and double-edged rings)
1. Slide the ring and nut onto the tube according to the diagram below.
2. Tighten the nut manually until hand-tight.
3. Pressing the tube against the stop in the connector, tighten the nut with a wrench by approximately 1.1/4 to 1.1/2 turns.
4. Bite check: Unscrew the nut and check if a collar covering the front part of the cutting edge has appeared. Rotation of the ring is permissible, but the ring must not move along the tube.
Reassembly: if the ring bite is correct, tighten the nut with the same force as during initial assembly. To achieve this, tighten the nut manually until hand-tight, then using a wrench, tighten by approximately 1/4 turn.

ASSEMBLY IN A VICE USING A PRE-ASSEMBLY DIE
Lubricate the thread and the working part of the assembly die
1. Slide the ring and nut onto the tube according to the diagram below.
2. Tighten the nut manually until hand-tight.
3. Pressing the tube against the stop in the die, tighten the nut with a wrench by approximately 1.1/4 turns.
4. Pre-assembly bite check: Unscrew the nut and check if a collar covering the front part of the cutting edge has appeared. Rotation of the ring is permissible, but the ring must not move along the tube.
Final assembly using the fitting body:
5. Tighten the nut manually until hand-tight.
6. Tighten the nut by approximately 1/4 turn.

ASSEMBLY USING A PRE-ASSEMBLY CUTTING RING DEVICE
1. Select the appropriate die and support plate, consistent with the tube diameter and fitting series.
2. Slide the ring and nut onto the tube according to the diagram below.
3. Place the tube with the ring and nut in the device between the die and the support plate.
4. Press the tube against the die stop.
5. Hold the tube steady in a position perpendicular to the device. Press and hold the START button until the pre-assembly process is automatically completed.
6. After the process is complete, remove the tube from the device.
7. Check if a collar covering the front part of the cutting edge has appeared. Rotation of the ring is permissible, but the ring must not move along the tube.
Final assembly: Tighten the nut manually until hand-tight, then with a wrench by approximately 1/4 turn.

SYSTEM DESCRIPTION
Cutting ring fittings provide easy and quick assembly of pipelines, guaranteeing a high level of installation safety.
The fitting consists of a body, a cutting ring, and a special nut. Depending on the pressure, three series of components are available: LL series for lowest pressures, L series for medium, and S series for highest pressures.
CUTTING RINGS
Double-edged ring (for L and S series) – is a standard ring offering very good connection tightness and compatibility with fittings according to DIN 2353. During assembly, the two cutting edges (1 and 2), thanks to their geometry sliding along the cone (3), bite into the tube surface creating a visible metal collar (5) covering the front cutting edge. Edge (1) bites into the tube earlier than edge (2), and after the bite, surface (6) blocks further edge penetration into the tube. The contact surface (4) provides additional tube support.

Single-edged ring (for LL series) – is a ring intended for low-pressure installations (maximum 100 bar). During assembly, the cutting edge (1) sliding along the cone bites into the tube surface creating a visible metal collar (4) covering the front part of the edge. The tube must be pushed against the fitting stop (2).

Example of a mounted ring on a hydraulic tube