Need help? Have a question? Call our sales team
Intermediate sleeve FI25 (for flaring)
Leave feedback on the product
Shipping costs are not included in the price.
Shipping costs are not included in the price.
Do darmowej dostawy brakuje Ci jedynie 100 zł
Masz darmową dostawę ✓
Product code: TUL POŚ FI 25
Barcode: 5905009151034
Our top pick :) Our warehouse packs orders until 3:00 PM, and GLS picks them up at 5:00 PM. It’s our customers’ most popular choice and the courier that works best for us.
Shipping cost for the selected product
The shipping cost applies to this product (in the selected variant - if applicable). It may change after adding other products to the cart.
Ask about the product
Administratorem danych osobowych jest HYDRON hydraulika siłowa . Przetwarzamy je w celu przesłania odpowiedzi na zapytanie. Więcej informacji dotyczących przetwarzania danych osobowych znajduje się w polityce prywatności.
Share the product card
Description
Intermediate sleeve FI25 for flaring hydraulic pipes – 25 mm
The FI25 intermediate sleeve for flaring is a hydraulic fitting component designed for making connections of rigid steel pipes with an outer diameter of 25 mm. It is used in flared connections, where the appropriately formed pipe end works with a matching connector, sleeve, and nut. The sleeve creates a supporting surface for the nut and helps transfer the clamping force to the prepared pipe end. It is used during the construction, repair, and modernization of power hydraulic systems.
The FI25 designation refers to the pipe's outer diameter of 25 mm. The product should be selected as part of a complete connection system. Diameter compatibility alone does not guarantee that the sleeve will fit every nut and every type of flare.
Technical parameters of the FI25 intermediate sleeve
- Product type: intermediate sleeve for pipe flaring.
- Size: FI25.
- Outer diameter of the matching pipe: 25 mm.
- Connection type: pipe, flared.
- Intended use: steel hydraulic pipes.
- Function: support for the flared pipe end and interaction with the nut.
- Matching elements: appropriately selected nut, connector, and FI25 pipe.
- Application area: power hydraulics and machine piping systems.
Application of FI25 sleeves in hydraulic systems
The FI25 intermediate sleeve is used to complete connections of steel pipe lines used in power hydraulics. This type of connection can be found in industrial machine installations, agricultural equipment, construction machinery, hydraulic power units, and other systems using rigid pipelines for hydraulic oil transport.
Pipes with an outer diameter of 25 mm can be used in various parts of the installation, including supply and return lines. However, the choice of pipe and connection is determined by the system design parameters, particularly the operating pressure, flow rate, wall thickness, and strength requirements of the entire assembly.
What function does the intermediate sleeve perform during flaring?
During the preparation of the connection, the end of the steel pipe is appropriately formed using a flaring tool. The resulting flare creates a surface that interacts with the connector. The intermediate sleeve is located on the nut side and acts as a support element, allowing the clamping force to be transferred to the flared end of the pipe.
A properly made flared connection enables the mechanical connection of the pipe line with the fittings. Its leak-tightness depends on the geometry of the flare, the condition of the mating surfaces, the compatibility of individual parts, and the correct tightening of the nut.
Selecting the sleeve for a 25 mm diameter steel pipe
The basic criterion for selecting the FI25 sleeve is the pipe's outer diameter of 25 mm. The wall thickness of the line, the type of flaring, and the design of the other connection components should also be checked. Pipes with the same outer diameter can have different wall thicknesses, therefore they require proper end preparation and compatibility with the flaring tool.
When completing the connection, a nut with the appropriate thread and a connector with a geometry matching the prepared flare must be selected. The FI25 pipe diameter does not automatically determine the connection thread. In the case of repairing an existing installation, it is worth comparing all elements with the previously used system.
Flaring sleeve vs cutting ring
An intermediate sleeve for flaring is not a replacement for a cutting ring. In a flared connection, the pipe end must be appropriately formed beforehand. In contrast, in systems with a cutting ring, the compression element interacts directly with the outer surface of the pipe. Both solutions require fittings of different designs.
The FI25 intermediate sleeve is also not a crimp sleeve for crimping flexible hydraulic hoses. Its purpose is for connecting rigid steel pipes, not for mounting fittings on rubber hoses.
Pipe preparation and flared connection assembly
Before starting assembly, check the pipe dimensions, surface condition, and compatibility of the connection components. The pipe end should be cut evenly, cleaned, and deburred. The nut and sleeve should be placed on the pipe in the correct order, according to the design of the system being used.
The flare should be made with the appropriate tool, and then its symmetry and the condition of the sealing surface should be checked. Ends with cracks, indentations, or other deformations should not be used. After tightening the connector, a leak test should be carried out according to the procedure applicable to the given hydraulic system.
Correct routing of FI25 hydraulic pipes
In installations with pipes having an outer diameter of 25 mm, it is important to properly support the lines and limit the stresses acting on the connections. The pipeline should be routed in a way that does not force displacement or deformation of the end when tightening the nut. In machines exposed to vibrations, proper placement of clamps and the operating conditions of the entire system must be taken into account.
Key advantages of the FI25 intermediate sleeve
- Intended for flared connections of steel hydraulic pipes.
- Size corresponding to an outer pipe diameter of 25 mm.
- Compatibility with a matching nut and connector.
- Support for the formed pipe end during tightening.
- Used during the creation of new hydraulic installations.
- Suitability for repairs and modernization of rigid pipelines.
- Ability to complete the connection from appropriately selected components.
Technical specification
| Parameter | Value |
|---|---|
| Name | Intermediate sleeve FI25 |
| Size | FI25 |
| Pipe outer diameter | 25 mm |
| Connection type | Flared |
| Intended use | Steel hydraulic pipes |
| Function | Flare support and interaction with the nut |
| Application | Pipe connections in power hydraulics |
Frequently Asked Questions (FAQ)
Which pipe does the FI25 intermediate sleeve fit?
The FI25 sleeve is designed for flared connections of steel pipes with an outer diameter of 25 mm. The compatibility of wall thickness and connector design should also be checked.
Is a nut required for the FI25 sleeve?
Yes. The sleeve works with an appropriately selected nut and connector. All parts must correspond to the flaring system used.
Does the FI25 sleeve replace a cutting ring?
No. An intermediate sleeve is a part of a flared connection, while a cutting ring is used in a different pipe joining system.
Is the FI25 sleeve suitable for hydraulic hose crimping?
No. The product is for connections of rigid steel pipes. Separate crimp sleeves are used for crimping flexible hydraulic hoses.
Product Reviews
If you've added a review and it doesn't appear on the list, it may be pending moderation.
Leave feedback on the product
Product Safety
Manufacturer
HYDRON hydraulika siłowa
Kujańska 6a
77-400 Złotów, Poland
+48 67 350 53 69 kontakt@hydron.com.pl Report a product safety issue
Responsible person in the EU
HYDRON hydraulika siłowa
Kujańska 6a
77-400 Złotów, Poland
+48 67 350 53 69 kontakt@hydron.com.pl Report a product safety issue