Skip to main content


Fluid power hydraulics - parts, accesories

Experienced Polish manufacturer & direct distributor of hydraulic components   
Retail & Wholesale – One-Stop Industrial Supplier | 100% European-owned    
   

six-time winner
Gazele Biznesu 2024

NATO supplier
Kod 99Q4H
Kod NCAGE Hydron

proven reliability
DUNS Numer Hydron

authorized
service
Autoryzowane centrum serwisowe ENERPAC w Polsce

official
distributorUSA
Autoryzowany dystrybutor ENERPAC w Polsce

official distributorUE SEMPERIT dystrybutor

quality assurance
ISO 9001, TUV
Certyfikaty Hydron ISO

📦 15,000+ items in our stock & ready to ship
⚡ Fast shipping 🛡️ Quality guarantee 🛠️ Technical support
Products in the cart: 0. See details
Your cart is empty
Need help? Have a question? Call our sales team

Thin-walled air conditioning hose DN12 G10

Go to Product feedback
with VAT without VAT
Price €12.00
incl. 23% VAT

Shipping costs are not included in the price.

lin. m.
Availability:
In stock
Darmowa przesyłka od 100 zł

Do darmowej dostawy brakuje Ci jedynie 100 zł

Masz darmową dostawę ✓

Manufacturer: HYDRON hydraulika siłowa (go to products)
Shipping time: 24 hours
Shipping from €3.64 - GLS Courier (Poland)

Our top pick :) Our warehouse packs orders until 3:00 PM, and GLS picks them up at 5:00 PM. It’s our customers’ most popular choice and the courier that works best for us.

Ask about the product
Share

Description

Thin-walled air conditioning hose DN12 G10 SAE J2064 35 bar

The thin-walled air conditioning hose DN12 G10 is designed for manufacturing flexible lines in the air conditioning systems of vehicles and machinery. The inner diameter is 12 mm, and the outer diameter is approximately 19.8 mm. The hose operates at a working pressure of up to 35 bar, features textile reinforcement, and meets SAE J2064 requirements. The operating temperature range is from -40°C to +135°C, momentarily up to +150°C.

Technical parameters

  • type: thin-walled air conditioning hose,
  • size: DN12 / G10,
  • inner diameter: 12 mm,
  • outer diameter: approximately 19.8 mm,
  • working pressure: 35 bar,
  • material: NBR,
  • reinforcement: textile braid,
  • standard: SAE J2064,
  • operating temperature: from -40°C to +135°C,
  • momentary temperature: up to +150°C,
  • color: black,
  • fitting assembly: crimping on a hydraulic press,
  • factory roll length: 50 m,
  • sales: per linear meter.

DN12 G10 what does this size mean?

DN12 refers to the internal diameter of the line, which is 12 mm, while G10 is the designation used when selecting air conditioning system components. When making a line, both designations must be checked, not just the hose diameter itself.

This is particularly important when choosing ferrules and fittings, as hoses with similar diameters may differ in wall construction and the required crimping system.

Thin-walled construction facilitates installation routing

With an inner diameter of 12 mm, the hose has an outer diameter of approximately 19.8 mm. The thin-walled construction allows for reducing the overall dimensions of the line and facilitates its routing in tight spaces typical of air conditioning installations.

This is a practical solution in engine compartments, agricultural machinery, and construction equipment, where the line often must run between other installations and structural elements.

Working pressure 35 bar

The DN12 G10 hose is designed to work at a maximum working pressure of 35 bar. This parameter should be taken into account when repairing an existing line or creating a new air conditioning installation.

In the case of a finished line, the allowable operating parameters also depend on the fittings and ferrules used, as well as the correctness of the crimp performed.

SAE J2064 – for professional air conditioning systems

The hose meets the requirements of SAE J2064, which is the standard used for flexible lines in air conditioning systems. This makes it suitable for professional repairs and the custom manufacturing of A/C lines.

Other thin-walled air conditioning hoses are also available in other diameters, allowing for the selection of the correct size for a specific installation.

Textile braid – flexibility and stability of the line

Textile reinforcement helps maintain the stability of the line during operation while simultaneously preserving the flexibility needed for installation in vehicles and machinery.

When routing the installation, avoid twisting the hose, sharp bends, and contact with elements that could damage its outer layer.

Operation from -40°C to +135°C

The operating temperature range is from -40°C to +135°C, and momentarily up to +150°C. This allows the hose to be used in variable thermal conditions typical for vehicles, working machinery, and mobile air conditioning systems.

What to use the DN12 G10 hose for?

  • car air conditioning systems,
  • truck and commercial vehicle air conditioning,
  • A/C systems in agricultural machinery,
  • construction machinery air conditioning,
  • repair of damaged air conditioning lines,
  • custom manufacturing of new A/C lines.

Ferrule for thin-walled hose DN12 G10

For correct crimping, a ferrule designed for the DN12 G10 size and the actual outer diameter of the hose must be selected. The HYDRON range includes the ferrule for thin-walled hose DN12 G10, intended for this system.

Ferrules should not be selected solely based on the DN12 designation. The construction of the hose and its outer diameter are also critical.

Thin-walled or thick-walled?

Lines with different wall constructions also exist in the G10 size. A thin-walled hose has a different outer diameter than the thick-walled version, so the crimping components must be selected for the specific type of hose.

If an old line is being replaced, it is worth measuring its outer diameter and checking the designation of the system used before purchasing.

What to check before purchasing?

  • if the required size is DN12 / G10,
  • if a thin-walled hose is needed,
  • if the outer diameter of approximately 19.8 mm matches the installation,
  • if the working pressure of 35 bar is appropriate,
  • if the fittings and ferrules are designed for the G10 system,
  • if the temperature range corresponds to the operating conditions.

Air conditioning hoses at HYDRON

At HYDRON, there are air conditioning hoses available in various diameters and designs, intended for repair and the manufacturing of new A/C lines.

When selecting, pay attention to the DN diameter, the G designation, thin-walled or thick-walled construction, and the compatibility of fittings and ferrules.

Frequently asked questions

What is the working pressure of the DN12 G10 hose?

The maximum working pressure is 35 bar.

What is the diameter of the hose?

The inner diameter is 12 mm, and the outer diameter is approximately 19.8 mm.

Does the hose meet SAE J2064?

Yes. The hose is designed for air conditioning systems and meets SAE J2064 requirements.

Is a specific ferrule needed for DN12 G10?

Yes. The ferrule must be selected for the thin-walled G10 hose and its actual outer diameter.

What is the operating temperature?

The operating temperature range is from -40°C to +135°C, and momentarily up to +150°C.

Product Reviews

Number of ratings: 3
Rate and review

Product Safety

Manufacturer

HYDRON hydraulika siłowa

Kujańska 6a

77-400 Złotów, Poland

+48 67 350 53 69 kontakt@hydron.com.pl Report a product safety issue

Responsible person in the EU

HYDRON hydraulika siłowa

Kujańska 6a

77-400 Złotów, Poland

+48 67 350 53 69 kontakt@hydron.com.pl Report a product safety issue

Other Products in This Category

    Bestsellers