Need help? Have a question? Call our sales team
Bulkhead fitting UNF 1.1/16"
Leave feedback on the product
Shipping costs are not included in the price.
Shipping costs are not included in the price.
You're only PLN 100 away from free shipping 100 zł
You've got free shipping ✓
Product code: ZN-141-1 1.1/16 UNF
Barcode: 5905009158453
The courier picks up parcels from us between around 1:00 and 2:00 PM.
Shipping cost for the selected product
The shipping cost applies to this product (in the selected variant - if applicable). It may change after adding other products to the cart.
Ask about the product
Administratorem danych osobowych jest HYDRON hydraulika siłowa . Przetwarzamy je w celu przesłania odpowiedzi na zapytanie. Więcej informacji dotyczących przetwarzania danych osobowych znajduje się w polityce prywatności.
Share the product card
Description
Bulkhead fitting UNF 1.1/16"
The UNF 1.1/16" bulkhead fitting is a connection element for power hydraulics, designed to provide a stable passage through a panel, bulkhead, bracket, housing, frame, or machine mounting plate. The product operates in the JIC 37° standard on a UNF 1.1/16" thread and has the same connection size on both sides. It is a screw-on bulkhead connector body, used where a hydraulic hose should not pass through the structure loosely but is to be fixed at a permanent point. Such a solution reduces stress, improves hose routing, and facilitates later system service.

Bulkhead fitting UNF 1.1/16" for bulkhead passage
In hydraulic machinery, a hose passage through a panel is a location particularly exposed to vibration, dirt, and mechanical stress. If the hose passes through a hole without stable mounting, it may rub against the edge, work on the fitting, or transfer loads to the thread. The UNF 1.1/16" bulkhead fitting creates a fixed connection point, allowing the installation on both sides of the bulkhead to be routed in a more controlled manner. Similar items can be found in the category JIC UNF bulkhead fittings.
JIC 1.1/16" thread and UNF standard
The product name includes UNF, while the technical parameters specify the size 1.1/16" JIC. In practice, this means a JIC 37° connection, which uses a UNF thread and a 37° cone as the mating surface. This fitting should not be selected solely by the thread diameter. It is necessary to confirm whether the mating element also operates in the JIC 37° standard. Inch threads may look similar but differ in pitch, sealing angle, and mounting method. Incorrect selection usually ends in leakage or damage to the conical surface.
The same size on both sides of the fitting
The UNF 1.1/16" bulkhead fitting is not a reduction. Both sides have the same connection size 1.1/16" JIC. This means that the larger thread and the smaller thread are the same, and the product's function is to stably route the connection through the bulkhead, not to change the diameter. The thread dimension given in the product data sheet is 26.6-26.9 mm external and 24.3-24.7 mm internal. When identifying an old part, it is worth checking not only the diameter but also the 37° cone, thread pitch, fitting standard, and the connection assembly method.
JIC 37° cone and connection tightness
In a JIC connection, tightness does not rely on the thread alone. The thread is responsible for pulling the elements together, while the actual seal is created on the 37° conical surface. Therefore, during assembly, you must check the cleanliness of the cone, the absence of scratches, the absence of dents, and the compatibility of the mating element. If the old hose end was over-tightened, the cone could have been deformed. In such a situation, replacing the bulkhead fitting alone may not solve the leak problem. You must evaluate the entire assembly: the fitting, the end, the hose, and the connection's operating conditions.
ISO 8434-2 and JIC 37° J514 standard
The product belongs to the JIC group of connectors complying with ISO 8434-2 and JIC 37° J514. This is important information when selecting replacements and identifying parts in imported machines. In such installations, JIC, ORFS, BSP, NPT, and metric can appear alongside each other, so the term "inch thread" alone is too general. If a passage in a different standard is needed, it is worth comparing this group with the category ORFS bulkhead fittings, because ORFS uses a different sealing method than JIC.
When a bulkhead fitting is better than a regular adapter
A regular adapter connects two elements but does not stabilize the passage through a panel. The UNF 1.1/16" bulkhead fitting has a different function. It allows for setting a connection point within the machine structure and keeping the hose in a predictable place. This is useful for hydraulic panels, housings, frames, brackets, and service passages. If the element is to be screwed directly into the body of a pump, valve, manifold, or cylinder, then appropriate straight hydraulic fittingsshould be selected, as a body connection requires a different selection than a bulkhead passage.
240 bar pressure and evaluation of the entire installation section
The working pressure of the fitting is 240 bar. This parameter applies to the element itself, but the entire installation section should be evaluated based on the weakest component. The limitation may be the hose, JIC end, tube, adapter, valve, or the element on the other side of the panel. If the previous connection leaked, replacing the fitting alone is not always enough. It is worth checking whether the hose is working under tension, if the 37° cone is damaged, and if there are pressure spikes in the system. For system monitoring, you can use hydraulic pressure gauges.
Assembly without hose tension
The bulkhead fitting should be mounted so that the hose on both sides of the panel does not force its position. A hose that is too short, an incorrectly positioned elbow fitting, or a hose routed at a sharp angle can put stress on the thread and the sealing cone. Leaks often do not appear immediately, but after several machine duty cycles, when the installation begins to transmit vibrations and variable pressure. When making a new section, it is worth ordering custom-made hydraulic hoses, tailored to the actual mounting location and fitting orientation.
Most common mistakes with UNF and JIC fittings
The most common mistake is confusing a JIC connection with another inch thread. The second mistake is selecting based solely on diameter, without checking the 37° cone. The third problem occurs when a bulkhead fitting is treated like a simple hose extension without being stably mounted in the panel. In JIC connections, the cleanliness of the conical surface, the absence of damage to the fitting, and correct hose routing are of great importance. If the hose passes close to the edge of the structure, it is worth using spiral guards for hydraulic hoses.
Comparison with other UNF bulkhead fittings
If the old part has been removed from the machine and has no legible marking, it is worth comparing adjacent sizes from the same family. For a smaller connection, you can check the UNF 7/8" bulkhead fitting, and for smaller hoses also UNF 9/16" bulkhead fitting. If the system is not made in the JIC standard, other hydraulic bulkhead fittingsshould be checked instead of matching the product by a similar thread diameter.
Fixing hoses at bulkhead passages
A bulkhead fitting stabilizes the passage point but should not be the only element supporting the hose. If the installation operates in vibrations, the hose is longer, or passes close to the machine structure, additional support should be planned. To stabilize pipes and hoses, use clamps and brackets for pipes and hoses. Good mounting reduces the movement of the installation, relieves the thread, and helps maintain the tightness of the conical connection.
Technical data of the product
- Product: bulkhead fitting UNF 1.1/16"
- Connector type: straight - connector, connection
- Purpose: bulkhead fitting
- Connection standard: JIC 37° on UNF thread
- Thread size 1: 1.1/16" JIC
- Thread 1 dimension: 26.6-26.9 mm external / 24.3-24.7 mm internal
- Thread size 2: 1.1/16" JIC
- Thread 2 dimension: 26.6-26.9 mm external / 24.3-24.7 mm internal
- Larger thread: no difference, both sides 1.1/16" JIC
- Smaller thread: no difference, both sides 1.1/16" JIC
- Working pressure: 240 bar
- Manufacturing standard: JIC ISO 8434-2 / JIC 37° J514 connectors
- Operating temperature: from -20°C to +120°C
- Material: free-cutting steel
- Surface protection: white passivated zinc plating
- Marking according to Rastelli Raccordi: BA.53.00.12
- Marking according to Vitillo: APPMJ12
- Marking according to Cast: 202006.3
- Alternative marking: XSV 1.1/16" / 6J-12
- Product code: ZN-141-1 1.1/16 UNF
- Barcode EAN: 2000010037193
Hydron assistance in selecting UNF bulkhead fittings
When selecting a UNF 1.1/16" bulkhead fitting, it is best to provide the thread size, JIC 37° standard, working pressure, mounting location, and information on whether the element passes through a panel, frame, housing, or hydraulic plate. Hydron provides bulkhead fittings, connectors, ends, hoses, tubes, guards, and mounting elements for power hydraulic systems. If you are not sure if the UNF 1.1/16" bulkhead fitting, another JIC size, ORFS, BSP, or metric variant will be correct, it is worth verifying the part before purchase.
FAQ
Is the UNF 1.1/16" bulkhead fitting used for panel mounting?
Yes. It is a bulkhead fitting designed for creating a stable passage through a panel, bulkhead, bracket, housing, or mounting plate.
What threads does the UNF 1.1/16" bulkhead fitting have?
The product has a 1.1/16" JIC connection on both sides, which is a JIC 37° connection on a UNF thread.
Which thread is larger in this fitting?
Both sides have the same size 1.1/16" JIC, so there is no difference between the larger and smaller thread.
What is the working pressure of the UNF 1.1/16" bulkhead fitting?
The working pressure is 240 bar. However, the entire hydraulic system should be evaluated according to the parameters of the weakest installation element.
What does JIC 37° mean?
JIC 37° means a conical connection where tightness depends on the correct contact of the 37° surfaces and the compatibility of the mating elements.
Can the UNF 1.1/16" fitting be used as a regular adapter?
It should not be treated as a regular adapter. It is a bulkhead fitting designed for mounting through a partition. If the element is to be screwed directly into a body, the correct connector must be selected.
What should be checked before purchasing a UNF 1.1/16" bulkhead fitting?
Before purchasing, check the 1.1/16" JIC size, JIC 37° standard, 240 bar working pressure, mounting location, and the mating elements on both sides of the bulkhead.
Product Reviews
If you've added a review and it doesn't appear on the list, it may be pending moderation.
Leave feedback on the product
Product Safety
Manufacturer
HYDRON hydraulika siłowa
Kujańska 6a
77-400 Złotów, Poland
+48 67 350 53 69 kontakt@hydron.com.pl Report a product safety issue
Responsible person in the EU
HYDRON hydraulika siłowa
Kujańska 6a
77-400 Złotów, Poland
+48 67 350 53 69 kontakt@hydron.com.pl Report a product safety issue