Need help? Have a question? Call our sales team
ORFS 1" Bulkhead Fitting
Leave feedback on the product
Shipping costs are not included in the price.
Shipping costs are not included in the price.
You're only PLN 100 away from free shipping 100 zł
You've got free shipping ✓
Product code: ZN-141-1 1 ORFS
Barcode: 5905009158392
The courier picks up parcels from us between around 1:00 and 2:00 PM.
Shipping cost for the selected product
The shipping cost applies to this product (in the selected variant - if applicable). It may change after adding other products to the cart.
Ask about the product
Administratorem danych osobowych jest HYDRON hydraulika siłowa . Przetwarzamy je w celu przesłania odpowiedzi na zapytanie. Więcej informacji dotyczących przetwarzania danych osobowych znajduje się w polityce prywatności.
Share the product card
Description
ORFS 1" Bulkhead Fitting
The ORFS 1" bulkhead fitting is an element used to make a stable hydraulic transition through a panel, bulkhead, mounting plate, frame, bracket, or other structural part of a machine. The product has 1" ORFS male threads on both sides, therefore it works as a straight bulkhead transition in a single standard, without changing the thread size. The fitting is equipped with a locknut, which allows the element to be seated in the hole and the connection point to be locked. In power hydraulics systems, such a solution is used when a hose, pipe, or connection point should not work loosely in the opening of the structure, but rather be routed in an orderly and safe manner for the connection.

ORFS 1" bulkhead fitting as a stable transition through a panel
A panel transition is a place where the hydraulic installation is often exposed to vibrations, stresses, and contact with the edge of the structure. If the hose passes through a hole without a fixed mounting point, it can transfer loads to the thread, fitting end, or sealing surface over time. The ORFS 1" bulkhead fitting allows the installation to be split on both sides of the partition and the connection point to be made in a more predictable manner for assembly and subsequent servicing. Similar solutions can be compared in the category ORFS bulkhead fittings.
1" ORFS thread on both sides of the fitting
In this product, both sides have the same 1" ORFS male thread. It is not a reducer or a transition to another standard, but a single-size bulkhead fitting. The thread dimension measured on the outside is 25.2-25.5 mm, and on the inside is 23.4-23.7 mm. The larger thread and the smaller thread are the same in this case because both connections have a 1" ORFS size. Despite this, the element should not be selected solely by caliper measurement. ORFS is a separate connection system and should not be confused with BSP, JIC, NPT, or other inch threads found in hydraulics.
ORFS seal and J1453 standard
ORFS stands for O-Ring Face Seal, which is a face connection with an O-ring seal. In such a solution, the thread is not directly responsible for leak-tightness, but for tightening the elements. The leak-tightness is created on the face surface with the participation of the appropriate O-ring. For this reason, during assembly, it is necessary to check the condition of the sealing face, surface cleanliness, O-ring selection, and the compatibility of the mating element with the ORFS J1453 standard. If the surface is scratched, dirty, or the previous O-ring was damaged, a leak can occur even with a correctly selected fitting.
When to use the ORFS 1" bulkhead fitting
The ORFS 1" bulkhead fitting is used in systems where a hydraulic hose or a section of the installation must pass through the machine structure and at the same time be seated at a fixed point. This can be a service panel, bracket, bulkhead, mounting plate, machine frame, or hydraulic housing wall. The product works well in mobile, industrial, agricultural, and construction machinery, as well as in installations where ORFS connections are used due to their leak-tightness and resistance to operation under high pressure. If a smaller variant is needed, you can compare the ORFS 13/16" bulkhead fitting, and for a larger transition, the ORFS 2" bulkhead fitting.
Locknut and seating in the bulkhead
The locknut allows the fitting to be secured in the bulkhead hole. This is important because a bulkhead transition should not just be a connection of two hoses. It must also stabilize the mounting point and limit the transfer of vibrations to the sealing surface. Before assembly, it is worth checking the hole diameter, panel thickness, access for tightening the locknut, and the hose routing on both sides. If the fitting is mounted under stress and the hose pulls it to the side, the ORFS seal may work in worse conditions and start leaking oil faster.
When not to treat a bulkhead fitting as an ordinary adapter
The ORFS 1" bulkhead fitting is not a regular adapter for the random connection of two elements with a similar thread. Its function is mounting through a partition. If the element is to be screwed directly into the body of a pump, valve, distributor, actuator, or hydraulic block, a connector designed for a given port must be selected. In such situations, it might be more appropriate to use straight hydraulic connectors. Selection by thread size alone can lead to incorrect sealing, face surface damage, or leaks after starting the system.
420 bar pressure and control of the entire system
The working pressure of the fitting is 420 bar. With such a parameter, you have to look at the entire section of the installation, and not just one element. The limitation can be a hose, fitting end, O-ring, pipe, valve, adapter, or a mating element on the other side of the panel. If the old fitting was leaking, it is worth checking whether the problem was not caused by a damaged face surface, worn O-ring, poorly routed hose, or excessive stresses at the transition point. To control the actual pressure in the system, you can use hydraulic pressure gauges.
Hose selection for the ORFS 1" bulkhead fitting
An ORFS connection works correctly when the hose is selected for the actual mounting location. A hose that is too short, an improperly positioned angled fitting end, or a bending radius that is too small can strain the fitting and the face surface. As a result, a leak may not appear immediately, but only after the machine has been running, when the system begins to transmit vibrations and variable pressure. When making a new section of the installation, it is worth ordering custom hydraulic hoses, matched to the length, routing direction, and type of ORFS fitting ends.
Most common errors with ORFS 1" fittings
The most common error is confusing ORFS with another inch thread, especially in imported machines, where JIC, NPT, BSP, and ORFS can be present next to each other. The second error is reusing an old O-ring or assembling the connection on a dirty face surface. The third problem is the lack of hose support on both sides of the bulkhead. A bulkhead fitting stabilizes the transition, but it should not carry the entire weight of the hose and the vibrations of the installation. If the hose can rub against the frame edge or a cover, it is worth using spiral guards for hydraulic hoses.
Mounting hoses and pipes at the bulkhead transition
The bulkhead transition should work with a well-routed installation. For longer sections, steel pipes, or hoses exposed to vibrations, additional mounting points should be planned. To stabilize hoses and pipes, you can use pipe and hose clamps and brackets. Good support reduces installation movement, relieves the thread, and helps maintain the leak-tightness of the face connection. This is especially important with larger ORFS hoses, which have a greater mass and can have a stronger impact on the transition point through the panel.
Products to compare when identifying parts
If the part removed from the machine does not have a legible marking, it is worth comparing several products from the same family. For smaller diameters, you can check the ORFS 11/16" bulkhead fitting or ORFS 13/16" bulkhead fitting. For large transitions, you can compare the ORFS 2" bulkhead fitting. If the installation is not made in the ORFS standard, you need to check other hydraulic bulkhead fittings, instead of matching the element by a similar thread diameter.
Product technical data
- Product: ORFS 1" bulkhead fitting
- Connection type: straight - connector, fitting
- Purpose: bulkhead fitting
- Thread 1: 1" ORFS
- Thread 1 dimension: 25.2-25.5 mm external / 23.4-23.7 mm internal
- Thread 2: 1" ORFS
- Thread 2 dimension: 25.2-25.5 mm external / 23.4-23.7 mm internal
- Larger thread: no difference, both sides 1" ORFS
- Smaller thread: no difference, both sides 1" ORFS
- Working pressure: 420 bar
- Execution standard: ORFS J1453 fittings
- Working temperature: from -20°C to +120°C
- Material: free-cutting steel
- Surface protection: white passivated zinc plating
- Execution: with a locknut, also known as a counter nut
- Vitillo designation: APPMO1313
- Cast designation: 6050-13
- Alternative designation: 6F-10
- Product code: ZN-141-1 1 ORFS
- EAN barcode: 2000010049424
Hydron assistance in selecting an ORFS bulkhead fitting
When selecting an ORFS 1" bulkhead fitting, it is best to provide the thread size, ORFS standard, working pressure, mounting location, and information on whether the element passes through a panel, frame, hydraulic plate, or other structural part. Hydron supplies bulkhead fittings, connectors, hoses, fitting ends, pipes, guards, and mounting elements for power hydraulics systems. If you are unsure whether an ORFS 1" bulkhead fitting, another ORFS size, a BSP fitting, or a metric variant will be correct, it is worth verifying the part before purchasing.
FAQ
Is the ORFS 1" bulkhead fitting used for mounting through a panel?
Yes. It is a bulkhead fitting designed to make a stable transition through a panel, bulkhead, wall, frame, or mounting plate.
What threads does the ORFS 1" bulkhead fitting have?
The product has 1" ORFS male threads on both sides.
Which thread is larger in this fitting?
Both sides have the same 1" ORFS size, so there is no difference between the larger and smaller thread. Before assembly, however, the ORFS standard must be confirmed.
What is the working pressure of the ORFS 1" bulkhead fitting?
The working pressure is 420 bar. However, the entire hydraulic system must be evaluated according to the parameters of the weakest element of the installation.
What does ORFS stand for?
ORFS stands for O-Ring Face Seal, which is a face connection with an O-ring seal. Such a system requires a compatible face surface and an appropriate O-ring.
Can this fitting be used as a regular adapter?
It shouldn't be treated as a regular adapter. It is a bulkhead fitting with a locknut, designed for mounting through a bulkhead or panel. If the element is to be screwed directly into a body, an appropriate connector must be selected.
What to check before buying an ORFS 1" fitting?
Before purchasing, you should check the 1" ORFS size, thread diameter, ORFS seal standard, 420 bar working pressure, mounting location, and mating elements on both sides of the bulkhead.
Product Reviews
If you've added a review and it doesn't appear on the list, it may be pending moderation.
Leave feedback on the product
Product Safety
Manufacturer
HYDRON hydraulika siłowa
Kujańska 6a
77-400 Złotów, Poland
+48 67 350 53 69 kontakt@hydron.com.pl Report a product safety issue
Responsible person in the EU
HYDRON hydraulika siłowa
Kujańska 6a
77-400 Złotów, Poland
+48 67 350 53 69 kontakt@hydron.com.pl Report a product safety issue