Bulkhead connector 3/4"ED / 1.7/16 ORFS

Go to Product feedback
with VAT without VAT
Price €9.08
incl. 23% VAT

Shipping costs are not included in the price.

pcs
Availability:
In stock
Free shipping on orders over PLN 100

You're only PLN 100 away from free shipping 100 zł

You've got free shipping ✓

Manufacturer: HYDRON hydraulika siłowa (go to products)
Shipping time: 24 hours
Shipping from €3.59 - InPost Parcel Lockers 24/7 (Poland)

The courier picks up parcels from us between around 1:00 and 2:00 PM.

Ask about the product
Share

Description

Bulkhead connector 3/4"ED / 1.7/16 ORFS

Bulkhead connector 3/4"ED / 1.7/16 ORFS is used to create a stable hydraulic passage through a panel, bulkhead, frame, bracket, mounting plate, or machine housing. On one side, there is a 3/4" BSP thread in ED execution, and on the other side, a 1.7/16 ORFS thread. This solution is used when the hydraulic installation must transition from a BSP connection to ORFS and simultaneously be fixed at a permanent point of the structure. The connector operates at pressures up to 315 bar, so during installation, one must check not only the thread size but also the seal type, the condition of the mating components, and the routing of the line.

Bulkhead connector 3-4-ED - 1-7-16 ORFS

 

BSP/ORFS bulkhead connector for panel passage

This product is not just a regular thread adapter. Its function is also to stably fix the connection point in the bulkhead. Thanks to this, the hose on the ORFS side and the element on the BSP side do not work loosely in the construction hole. This is important in mobile machines, hydraulic assemblies, service panels, and industrial systems where the hose should be routed in an organized and vibration-resistant manner. Other variants in this group can be compared in the category BSP/ORFS bulkhead connectors.

3/4" BSP ED and 1.7/16 ORFS thread in one component

This connector features two different hydraulic standards. The 3/4" BSP side has an external dimension of 26.1-26.4 mm, while the 1.7/16 ORFS side has an external dimension of 36.2-36.5 mm. The larger thread is 1.7/16 ORFS, and the smaller thread is 3/4" BSP. Therefore, when selecting, it is not enough to simply specify "inch thread". You must confirm the connection standard, seal type, and the mating element on both sides of the bulkhead. Confusing ORFS with JIC or BSP with another pipe thread can lead to leaks despite the seemingly similar diameter.

What ED means on the BSP side

The ED designation on the 3/4" BSP thread indicates a connection with an elastomeric seal. The BSP side should not be treated as any pipe thread tightened solely on the thread. The mating component must be compatible with this sealing method. If the socket, adapter, or fitting on the BSP side operates in a different standard, simply tightening the connector will not guarantee leak-tightness. Before assembly, it is worth checking the contact surface, the condition of the seal, thread cleanliness, and signs of previous tightening.

ORFS 1.7/16 and face seal

The 1.7/16 ORFS side operates in the O-Ring Face Seal system. In such a connection, the thread is responsible for tightening the components, but the seal is created on the face surface with the participation of an O-ring. Therefore, it is necessary to check whether the hose end, adapter, or other element on the ORFS side has a compatible geometry, a clean face, and an undamaged seal. To compare elements in the ORFS standard itself, the category will be useful ORFS bulkhead connectors.

When to use the 3/4"ED / 1.7/16 ORFS connector

The 3/4"ED / 1.7/16 ORFS bulkhead connector works well in installations where one side of the system operates in the BSP ED standard and the other in the ORFS standard. This may apply to machine modernization, repair of an existing hydraulic panel, passage through a frame, connection of a hose to an auxiliary block, or replacement of an installation fragment where the manufacturer used different connection standards. In such a case, the bulkhead fitting allows for a fixed mounting point and reduces the risk of the hose working directly on the thread.

Do not use a bulkhead fitting as a random reduction

A bulkhead connector should not replace a body fitting. If the element is to be screwed directly into a pump, cylinder, valve bank, valve, or hydraulic block, a part suitable for the specific socket and sealing method must be selected. For such connections, use straight hydraulic fittings. The bulkhead fitting has a different task: it carries the installation through the panel and stabilizes the connection point on both sides of the structure.

Operating pressure 315 bar and control of the entire system

The operating pressure of this connector is 315 bar. This parameter applies to the component itself, but the entire hydraulic system must be evaluated according to the weakest component. The limitation may be the hose, ORFS end, O-ring, adapter, valve, BSP socket, or the element on the other side of the bulkhead. If the previous connection was leaking, it is worth checking if the problem was caused by a damaged ORFS face, an incompatible ED seal, or a hose working under tension. For monitoring system parameters, hydraulic pressure gaugesare useful.

Assembly through the bulkhead without stressing the hose

During installation, the connector should be stably seated in the hole, and the hose on both sides should not force its position. A hose that is too short, an incorrectly positioned elbow fitting, or a rigid pipe routed under tension can stress the thread and the sealing surface. Leaks often appear only after machine operation, when the installation starts transmitting vibrations and variable pressure. When creating a new section, it is worth ordering custom-made hydraulic hoses, adapted to the actual installation site.

Most common errors in BSP/ORFS selection

The most common error is identifying the product by thread diameter alone. The second is confusing ORFS with another inch standard, particularly JIC. The third problem occurs when the BSP side is treated as a regular thread without taking the ED seal into account. For this connector, both standards must be confirmed: 3/4" BSP ED and 1.7/16 ORFS. If the old element was tightened multiple times, the condition of the sealing surfaces and mating components should also be checked.

Protection and mounting at the bulkhead passage

The passage through the panel is often located near an edge, frame, or machine guard. The connector itself stabilizes the connection point, but it does not protect the entire hose route. If the hose could rub against the structure, it is worth using spiral guards for hydraulic hoses. For longer hoses or pipes, additional support points are also required. For this purpose, clamps and clips for pipes and hosesare used, which limit vibrations and relieve the bulkhead connection.

Products to compare for part identification

If the disassembled part does not have legible markings, it is best to compare the standards separately. On the BSP side, a BSP 3/4" bulkhead connectorcan be helpful. On the ORFS side, it is worth comparing the ORFS 1.7/16" bulkhead connector or the smaller ORFS 1.3/16" bulkhead connector. Such a comparison reduces the risk of purchasing a visually similar element that operates in a different sealing system.

Product technical data

  • Product: bulkhead connector 3/4"ED / 1.7/16 ORFS
  • Connector type: straight - connector, fitting
  • Connection standard: BSP ED / ORFS
  • Thread size 1: 3/4" BSP
  • Thread dimension 1: 26.1-26.4 mm external / 24.1-24.5 mm internal
  • Thread size 2: 1.7/16 ORFS
  • Thread dimension 2: 36.2-36.5 mm external / 34.0-34.4 mm internal
  • Smaller thread: 3/4" BSP
  • Larger thread: 1.7/16 ORFS
  • Intended use: bulkhead connector, BSP/ORFS passage
  • Operating pressure: 315 bar
  • Execution standard: ORFS J1453 connectors
  • Polish Standard: PN-65 M73141, straight fittings
  • Operating temperature: from -20°C to +120°C
  • Material: free-cutting steel
  • Surface protection: zinc plating in white passivation
  • Product code: ZN-141-1 3/4/1,7/16
  • EAN barcode: 0200000032524

Hydron technical support in BSP/ORFS connector selection

When selecting a 3/4"ED / 1.7/16 ORFS bulkhead connector, it is best to provide both threads, the seal type, operating pressure, and the installation location in the machine. Hydron helps in selecting bulkhead connectors, hoses, ends, fittings, seals, and mounting elements for power hydraulic systems. Verification before purchase reduces the risk of error, shortens repair time, and decreases the number of repeat installation disassemblies.

FAQ

Is the 3/4"ED / 1.7/16 ORFS bulkhead connector used for panel mounting?

Yes. This is a bulkhead connector designed to create a stable passage through a panel, bulkhead, frame, bracket, or mounting plate.

What threads does the 3/4"ED / 1.7/16 ORFS connector have?

The product has a 3/4" BSP thread on one side and a 1.7/16 ORFS thread on the other side.

Which thread is larger?

The larger thread is 1.7/16 ORFS, and the smaller thread is 3/4" BSP. The difference should be confirmed by measurement and sealing standard.

What is the operating pressure of this connector?

The operating pressure is 315 bar. However, the entire hydraulic system must be evaluated according to the parameters of the weakest component of the installation.

What does ORFS mean?

ORFS stands for O-Ring Face Seal, which is a face connection with an O-ring seal. Leak-tightness depends on the face surface and proper sealing, rather than the thread itself.

Can this connector be used as a regular reduction?

It should not be treated as a simple reduction. This is a bulkhead connector for installation through a partition. To screw directly into the body of a pump, valve, or valve bank, an appropriate fitting should be selected.

What to check before buying a 3/4"ED / 1.7/16 ORFS connector?

Before buying, you should check the 3/4" BSP thread, the 1.7/16 ORFS thread, the ED seal type, the ORFS J1453 standard, the 315 bar operating pressure, and the installation location in the bulkhead.

Product Reviews

Number of ratings: 1
Rate and review

Product Safety

Manufacturer

HYDRON hydraulika siłowa

Kujańska 6a

77-400 Złotów, Poland

+48 67 350 53 69 kontakt@hydron.com.pl Report a product safety issue

Responsible person in the EU

HYDRON hydraulika siłowa

Kujańska 6a

77-400 Złotów, Poland

+48 67 350 53 69 kontakt@hydron.com.pl Report a product safety issue